Commercial Service
Janazzo Services Corporation has been offering premium service agreements
for Commercial Customers for over (50) years and would like to have
you as a customer.
We Offer:
- Competitive rates
- 10% Discounts on parts and labor
- Customized service agreements personalized for your account.
- (84) Eighty-four point checklist on your Air Conditioning & Heating system .
- Detailed Log Sheet (not just check marks) on each piece of equipment confirming you are getting the quality inspection you deserve.
- Filters, Belts, Lubricants & Biodegradable coil cleaning chemicals included in service agreement.(No Extra Charge)
- Equipment History individually tracked on our computer database
- (24) Twenty-four hour (7) seven-day emergency service.
We Offer:
- Customized Design/Build installation of HVAC systems.
- Complete in-house fiberglass/metal ductwork fabrication.
- Over (50) Years of experience in Industrial/Commercial, Health Care Facilities, Schools, Office and Retail Applications.
CHECK US OUT AND SEE WHAT JANAZZO SERVICES CORPORATION CAN OFFER YOU.
PLAN A, P, X(Standard Gas Furnace)
(Pulse & Condensing Type)(Complete Heat)
- Check automatic controls
- Clean burners as needed
- Check and clean heat exchanger as needed
- Inspect for combustion leaks
- Test flue for satisfactory operation
- Check for proper fuel consumption
- Check manifold gas pressure
- Check temperature rise per manufacturer's specification
- Check CO2, O2,and test for Carbon Monoxide
- Adjust combustion for optimum efficiency
- Lubricate moving parts as needed
- Test safety and operating controls
- Lubricate motors and bearings as required
- Check belt wear, tension and alignment (if applicable)
- Inspect air blower wheel
- Replace disposable air filters
- Check flame signal readings
- Check thermostat operation
- Record detailed information on log sheet
PLAN AH (Air Handler)
- Check fins and clean coil
- Check electrical connections for tightness
- Check blower belt wear,tension and alignment
- Inspect air blower wheel
- Lubricate motors and moving parts as required
- Check voltage and amperage readings
- Replace disposable air filters
- Check thermostat operation
- Record detailed information on log sheet
Plan AP (Air Purifier)
- Check power to unit
- Check electrical connections
- Check airflow switch
- Check voltage readings
- Annual maintenance kit (filter, metal insert and UV lights)
- Record detailed information on log sheet
Plan B (Oil Furnace)
- Clean and adjust electrodes
- Clean and inspect burner tube,burner blower wheel,
cad cell,fuel pump strainer, and primary air band
- Replace fuel oil nozzle and fuel oil filter cartridge
- Lubricate burner motor, inspect combustion chamber
operating controls, safety controls, and breaching
- Clean fuel passageways(heat exchanger section) and breaching
- Inspect blower for proper operation
- Check belt wear, tension and alignment (if applicable)
- Lubricate blower motor and bearings as required
- Replace disposable air filters
- Check draft over fire and breaching
- Check CO2, O2, Smoke and Carbon Monoxide
- Adjust System for optimum efficiency
- Check temperature rise per manufacturer's specification
- Check thermostat operation
- Record detailed information on log sheets
Plan C (Air Conditioner)
- Check fins and clean condensor coil
- Check electrical connections for tightness
- Visually check for oil and refrigerant leaks
- Check blower belt wear, tension and alignment (if applicable)
- Replace disposable air filters
- Check and clean condensate drain
- Inspect air blower wheel
- Lubricate motors and moving parts as required
- Check refrigerant operation pressures
- Check sub-cooling and superheat readings
- Check temperature drop across evaporator coil
- Check voltage and amperage readings
- Check thermostat operation
- Record detailed information on log sheet
Plan D (Heat Pump)
- Lubricate motors and moving parts as needed
- Check defrost cycle and reversing valve operation
- Inspect air blower wheel
- Check blower belt wear, tension and alignment
- Visually check for oil and refrigerant leaks
- Check electrical controls and crankcase heater
- Replace disposable air filters
- Check and clean condensate drain
- Check and tighten electrical connections
- Check voltage and and amperage readings
- Check operating pressures and temperatures
- Check auxillary heat for proper operation
- Check temperature across air handler
- Check Thermostat operation
- Record detailed information on log sheet
Plan E (Electric Furnace)
- Check operation of controls
- Check all wiring for loose connections and condition of insulation
- Check voltage supply and amperage readings
- Lubricate blower motor and moving parts as required
- Inspect blower wheel
- Check belt wear, tension and alignment (if applicable)
- Replace disposable air filters
- Check blower operation and staging of heating elements
- Check thermostat operation
- Record detailed information on log sheet
Plan EAC (Electric Air Cleaner)
- Check power to unit
- Check electrical connections
- Check airflow switch
- Check voltage readings
- Remove and clean electronic cells and pre-filters
- Record detailed information on log sheet
Plan G (Gas Boiler)
- Check automatic controls
- Clean burners as needed
- Check and clean heat exchanger as needed
- Inspect for combustion leaks
- Test flue for satisfactory operation
- Lubricate moving parts as required
- Check for proper fuel consumption
- Check manifold gas pressure
- Check CO2, O2, Smoke and Carbon Monoxide
- Adjust combustion for optimum efficiency
- Test safety and operation controls
- Check voltage and amperage readings
- Check flame signal readings
- Chek thermostat operation
- Check circulator and zone valve operation
- Record detailed information on log sheet
Plan GEN (Generator)
- Check automatic controls
- Check electrical connections for tightness
- Replace spark plugs
- Replace crankcase oil
- Replace oil filter
- Lubricate moving parts as needed
- Check and clean battery leads
- Check operation of battery charger
- Replace air filter
- Check voltage and amperage readings
- Check manifold pressure readings and input
- Check operating and safety controls
- Visually check for leaks
- Record detailed information on log sheet
Plan HUM (Humidifier)
- Clean drain pan (replace if disposable type)
- Clean and adjust float assembly
- Remove and replace pad
- Check motor operation (if applicable)
- Check heating elements (if applicable)
- Check operating and safety controls
- Check drain (if applicable)
- Check voltage and amperage readings
- Check humidistat setting and operation
- Record detailed information on log sheet
Plan HWE (Electric Hot Water Heater)
- Check condition of insulation on wiring
- Check electrical connections for tightness
- Check voltage and amperage readings
- Check operation of heating elements
- Check operating and safety controls
- Record detailed information on log sheet
Plan HWG (Gas Hot Water Heater)
- Check automatic controls
- Clean burners as needed
- Check and clean heat exchangers as needed
- Inspect for combustion leaks
- Test flue for satisfactory operation
- Lubricate moving parts as required
- Check for proper fuel consumption
- Check manifold gas pressure
- Check CO2,O2, and test for Carbon Monoxide
- Adjust combustion for optimum efficiency
- Test safety and operating controls
- Check voltage and amperage readings
- Check flame signal readings
- Check thermostat operation
- Record detailed information on log sheet
Plan HWO(Oil Water Heater)
- Clean and adjust electrodes,burner blower wheel,
cad cell,fuel pump strainer, and primary air band
- Replace fuel oil nozzle and fuel oil filter cartridge
- Lubricate burner motor, inspect combustion chamber, operating
controls and safety controls
- Clean flue passageways and breaching
- Check draft over fire and breaching
- Check CO2,O2, Smoke and Carbon Monoxide
- Adjust system for optimum efficiency
- Lubricate motors and moving parts as required
- Check circulator if applicable
- Check voltage and amperage readings
- Check thermostat operation
- Record detailed information on log sheet
Plan O (Oil Boiler)
- Clean and adjust electrodes, burner blower wheel,
cad cell,fuel pump strainer, and primary air band
- Replace fuel oil nozzle and fuel oil filter cartridge
- Lubricate burner motor, inspect combustion chamber, operating
controls and safety controls
- Clean flue passageways (boiler sections and breaching)
- Inspect and lubricate circulator, drain expansion tank as necessary
- Check draft over fire and breaching
- Check CO2,O2, Smoke and Carbon Monoxide
- Adjust system for optimum efficiency
- Lubricate motors and moving parts as required
- Check circulator and zone valve operation
- Check voltage and amperage readings
- Check thermostat operation
- Record detailed information on log sheet
|